Cooling
Read the latest news and updates from the Open Compute Project.
Browse 103 news articles
-
COOLWAVE™ DC HEAT TRANSFER FLUIDS
COOLWAVE™ DC 25 Heat Transfer Fluid is a high-performance USP-grade propylene glycol-based coolant engineered for next-generation Datacom Equipment Cooling Systems (DECS) and data center liquid cooling supporting AI and high-performance computing (HPC) workloads. The fluid meets or… -
-
Sensata 35CP Pressure Sensors – 35CP1X
Sensata’s 35CP1X pressure sensor delivers on the performance and technical requirements needed to monitor pressure around coolant distribution unit pumps, with a broad operating temperature range (-30°C to +100°C ) and operating pressure ranges from 0~10bar… -
-
Castrol ON Direct Liquid Cooling PG 25
“Castrol ON Direct Liquid Cooling PG 25” (or PG 25) is a propylene glycol-based heat transfer fluid developed by Castrol for data center direct-to-chip cooling, designed for high-performance servers, offering corrosion protection, biostability, and simplified usage… -
-
Dynalene PG-D25 Propylene Glycol Based Data Center DTC Heat Transfer Fluid (PG 25)
Dynalene’s PG-D coolant series delivers direct liquid cooling solutions for data centers, AI and high-performance computing. These non-toxic DTC coolants are fully formulated propylene glycol-water solutions blended with a proprietary inhibitor package. If on-site dilution is… -
-
Georg Fischer LiquidCore In-rack Manifold
The in-rack manifold is a custom-engineered polymer distribution unit designed to distribute coolant to every server tray within the rack evenly, ensuring consistent flow and stable chip temperatures under the highest computational loads. -
-
FITOK Universal Quick Disconnect (UQD)
FITOK UQD Series Universal Quick Disconnect provides convenient operation and reliable performance for rapid coupling and decoupling between rack servers and coolant supply/return manifolds in data center thermal management systems. Designed in accordance with the OCP… -
-
Nidec – Project Deschutes 5 CDU
Nidec’s In-Row CDU for open standards is built to Google’s Project Deschutes 5 OCP-compliant specification, delivering 2MW of cooling capacity to support high-density AI infrastructure. Nidec is the only Japanese vendor for this project, backed by… -
-
Sensata PGFM Series GFCI Sensing Modules
The LineGard™ PGFM product family – operating in tandem with an an Airpax™ LEL series, UL 489 listed circuit breaker, with shunt trip and auxiliary switch – provides ground fault circuit interruption (GFCI) protection for generator,… -
-
SOLUTHERM™ OAT PG 25 Heat Transfer Fluid
SOLUTHERM™ OAT PG 25 Heat Transfer Fluid is a ready-to-use, propylene glycol-based thermal management fluid designed for the unique needs of Direct Liquid Cooling (DLC) in data centers, supercomputers, and adjacent end uses. The fluid offers… -
-
SK picglobal’s Propylene Glycol-based Heat Transfer Fluid (HTF) PG 25
SK picglobal’s Propylene Glycol-based Heat Transfer Fluid (HTF) PG 25 is a high-purity, low- toxicity solution designed to meet the rigorous thermal management needs of data centers and industrial cooling applications. Formulated with advanced corrosion inhibitors and… -