Physical Infrastructure

Read the latest news and updates from the Open Compute Project.

Browse 227 news articles

  1. Oventrop

    Manual Balancing Valve

    Oventrop manual balancing valves are installed in hot water central heating systems and chilled water A/C systems with a closed water circuit. They are designed to achieve hydronic balancing between the various circuits of the system,…
  2. Americase

    CoreVault™ Cold Aisle Component Cases

    CoreVault™ Cold Aisle Rack Infrastructure Packaging Solutions: Robust, reusable containers engineered for the front-of-rack hardware. These custom-designed packaging systems enable rapid in-aisle swaps, keep GPUs, switches, CDUs, and other mission-critical OEM components safe in transport, storage,…
  3. Cooler Master

    OCP – Deschutes 5 In-Row CDU

    The OCP – Deschutes 5 CDU is a next-generation, high-capacity liquid-cooling distribution unit defined by Google and contributed to the Open Compute Project (OCP) to accelerate industry-wide adoption of liquid cooling at scale.Designed for AI/ML and…
  4. Danfoss

    Danfoss MBT 3560 Temperature Sensor

    Danfoss MBT 3560 is a compact, high-accuracy temperature transmitter designed for data center liquid cooling applications, including CDUs, liquid cooling loops, and facility water systems. Combining a precision sensing element with an integrated transmitter, it delivers…
  5. Gems Setra

    3510 Series Pressure Transducer

    The 3510 Series Pressure Sensor offers compound pressure measurement for both positive and vacuum pressure monitoring, ideal for leak testing and pump-down applications in data center liquid cooling systems. Its 316L stainless steel wetted parts support…
  6. Teledyne LeCroy

    HDO6000B High Definition Oscilloscope

    The HDO6000B High Definition Oscilloscope is a 12-bit, 4-channel, up to 1 GHz bandwidth oscilloscope with 250 Mpts of memory. It is optimized for the accuracy needed for data center power supply units (PSUs) design and…
  7. Teledyne LeCroy

    DL-HCM

    With 60 V common mode and 80 V dynamic range, the DL-HCM differential voltage probes are optimized for 48 V ORV3 Power Supply Units (PSUs). It has 0.5% DC gain accuracy and bandwidth from 250 MHz…
  8. Danfoss

    Danfoss DST P110 Pressure Sensor

    Danfoss DST P1xx is a high-accuracy pressure sensor designed for data center liquid cooling applications, including CDUs, rack manifolds, and facility water systems. Built on proven MEMS technology, it delivers reliable pressure monitoring and supports differential…
  9. Emyte Fluid Technology (Jiangsu) Co., Ltd.

    Emyte Universal Quick Disconnect (UQD)

    Emyte UQD series are OCP‑compliant dry‑break quick couplings for data center direct‑to‑chip liquid‑cooling infrastructure. Designed per OCP UQD specification, these tool‑free push‑to‑connect connectors deliver minimal spillage, low‑pressure‑drop flow performance and cross‑vendor interoperability. Constructed from corrosion‑resistant stainless…
  10. IMI Hydronic Engineering

    Zeparo Aero ZAIX

    Industrial microbubble separator in Stainless Steel DN50 – DN300 For applications of all sizes, the Zeparo range offers a reliable solution to issues with microbubbles in heating, solar, and chilled water systems. The Helistill separator makes…